Part L of the Building Regulations when renovating a home

Last updated

Part L of the Building Regulations sets the energy efficiency standards for buildings in England. Most people hear about it when building an extension, but it can also apply when you renovate an existing house: replacing windows, re-roofing, stripping walls back to brick or converting a garage or loft into a room.

This guide explains in general terms when Part L is likely to be triggered during renovation work and what that usually means in practice. Our separate guide on insulation and energy efficiency in extensions covers new-build extensions. FirstR8 Builds carries out refurbishments and offers a free, no-obligation initial site consultation.

Home refurbishment in progress by FirstR8 Builds, West Sussex

In short

Part L applies when you replace windows or doors, renovate a large proportion of a wall, floor or roof, convert a non-heated space into a room, or replace heating or hot water systems. In those cases the new work normally has to meet set insulation or efficiency levels, so far as is technically and economically reasonable. Small repairs and redecoration are usually outside it.

What Part L is for

Part L, conservation of fuel and power, aims to reduce heat loss and energy use. Approved Document L Volume 1 covers dwellings and sets limiting values for how much heat may pass through walls, roofs, floors, windows and doors, measured as U-values. The lower the U-value, the better the insulation. It also covers heating, hot water, lighting and how new systems are commissioned.

The standards were tightened in June 2022, so advice based on older rules may be out of date. Building control or your designer will confirm the current figures for your project.

Renovating walls, floors and roofs

When you renovate a thermal element, meaning an external wall, roof or ground floor, Part L may require it to be upgraded. The usual trigger is renovating more than 50 percent of that element's surface area, or replacing the whole layer, such as stripping plaster back to brick on an outside wall or taking a pitched roof back to the rafters.

Where triggered, the element normally needs insulating to an improved standard, unless that would not be technically, functionally or economically reasonable, for example where it would take up too much room or not pay back over a reasonable period. This is a judgement building control can help with, and older solid-walled houses often need breathable insulation solutions to avoid trapping moisture.

Replacing windows and doors

Replacement windows, roof lights and external doors have to meet minimum energy performance standards. If you use an installer registered with a competent person scheme, they can self-certify the work and notify building control for you. If not, a building control application is normally needed.

Replacement windows must also not make other things worse. For example, new windows should keep or improve trickle ventilation, and escape windows in bedrooms should still provide a suitable opening.

Converting a loft, garage or outbuilding

Turning an unheated space into a habitable room, such as a garage or loft conversion, is a change of energy status. The walls, floor and roof of the new room will usually need to reach the standards for new thermal elements, and any new windows must comply. That is why a garage conversion normally includes new floor insulation, insulated walls and a properly insulated ceiling or roof. Our garage conversion guide explains this in more detail.

Heating, hot water and lighting

Replacing a boiler or hot water cylinder, adding radiators or fitting new heating controls falls under Part L, and gas work must be done by a Gas Safe registered engineer who notifies it. New fixed lighting is expected to be energy efficient. These items are usually handled by the specialist trades on a refurbishment, but they should be coordinated with the building work.

Avoiding condensation and damp

Adding insulation without thinking about moisture can cause problems. Internal insulation on old walls can move the dew point, cold spots at junctions can attract mould, and tighter windows reduce background ventilation. Part F, which covers ventilation, works alongside Part L, so an upgrade often needs extractor fans or trickle vents too. A good refurbishment plan considers insulation, airtightness and ventilation together.

Mistakes to avoid

  • Stripping an external wall back to brick and replastering without asking whether Part L applies.
  • Using non-breathable insulation on solid walls in an older property.
  • Fitting windows from an installer who cannot self-certify and not notifying building control.
  • Leaving gaps in insulation at corners, window reveals and floor junctions.
  • Forgetting ventilation after making the house more airtight.

Frequently asked questions

Does Part L apply to replacing windows?
Yes. Replacement windows and external doors must meet minimum energy standards and be notified, either by a competent person scheme installer or through building control.
Do I have to insulate walls when I replaster?
If you renovate more than half of an external wall's area, such as stripping it back to brick, Part L may require an upgrade where it is technically and economically reasonable.
Does a garage conversion need to meet Part L?
Yes. Turning an unheated garage into a room normally means the walls, floor, roof and windows must meet current insulation standards.
When did Part L last change?
The standards were updated in June 2022 in England, so check that advice and specifications reflect the current version.
Is redecorating covered by Part L?
No. Painting, minor repairs and small patches of plaster are generally outside Part L. It applies to larger renovations of thermal elements and certain replacements.