Does your home project need planning permission?

An extension, loft conversion or garden building may be possible without a householder planning application, but that does not mean there are no planning rules. Permitted development, usually shortened to PD, is planning permission granted nationally for specified work, subject to detailed limits and conditions. Your address, the house’s history and the whole design all matter.

This guide explains the main householder rules in England and how to choose the right approval route in West Sussex. It is a starting point, not confirmation that your proposal is lawful. Check the current Planning Portal guidance and your local planning authority before ordering materials or starting work, especially where previous additions or protected areas complicate the position.

House extension and loft conversion work by FirstR8 Builds in West Sussex

Start with the original house and its planning history

PD limits often refer to the original house: the house as first built, or as it stood on 1 July 1948 if older. An extension built by a previous owner does not reset that baseline. Establish the original footprint using planning records, dated drawings and other reliable evidence before measuring a new addition.

For extensions, buildings and additions must not cover more than 50% of the land around the original house. This is not simply half the rear garden. The calculation excludes the original house footprint but includes existing extensions, sheds and other outbuildings. Outbuildings also have a related coverage restriction, so assess the plot as a whole rather than treating each project separately.

Householder PD rights do not apply to flats or maisonettes in the same way as houses. Certain homes created through change-of-use PD routes also lack these rights. For eligible houses, check decision notices for conditions removing rights and ask about Article 4 directions, which can withdraw specified rights locally. Some estates have restrictions imposed when their original planning permission was granted.

Single-storey rear extensions: standard and larger limits

Under the standard householder PD limits, a single-storey rear extension can project up to 4 metres beyond the original rear wall of a detached house, or 3 metres for any other house. Its overall height must not exceed 4 metres. Other conditions still apply: being below those dimensions alone does not establish permission.

The larger home extension route can allow up to 8 metres for a detached house or 6 metres for another house. This requires the neighbour consultation and prior approval procedure before work begins; it is not an automatic allowance. It is unavailable on designated land, including conservation areas and national parks, and on Sites of Special Scientific Interest. Ask the council which application and supporting drawings it needs.

Through that procedure, the council notifies adjoining owners or occupiers. If objections are received, it considers the impact on the amenity of adjoining premises. A neighbour’s support does not override the statutory limits, and an objection is not automatically a refusal. Follow the council’s written outcome and procedural requirements rather than assuming a submitted form authorises construction.

  • If any part of the extension comes within 2 metres of a boundary, its eaves must not exceed 3 metres in height.
  • Extension eaves cannot exceed the existing house’s eaves, and the extension cannot exceed the highest part of its existing roof.
  • External materials generally need to be similar in appearance to the existing house; conservatories have an exception to this condition.

Side extensions and two-storey rear additions

A side extension under the usual PD rules must be single storey, no higher than 4 metres and no wider than half the width of the original house. The boundary eaves restriction still applies. Side extensions are not permitted development on designated land. A wraparound design must satisfy all relevant side and rear rules together; a compliant rear element does not make the side element lawful.

For an extension of more than one storey, the rear projection must not exceed 3 metres beyond the original rear wall. It must also be at least 7 metres from any boundary opposite the rear wall. Extensions of more than one storey are not PD on designated land. The overall roof and eaves limits remain relevant, and the roof pitch should match the original house as far as practicable.

Upper-floor windows in a side elevation must meet obscure-glazing and restricted-opening conditions. Balconies, verandas and raised platforms are excluded from these extension rights. Extensions forward of the principal elevation, or forward of a side elevation facing a highway, are also outside the normal allowance. Corner plots and stepped rear walls deserve particular care when interpreting these rules.

Loft conversions: roof volume is only one test

The roof enlargement allowance is up to 40 cubic metres of additional roof space for terraced houses and 50 cubic metres for other houses. These are cumulative allowances: previous roof enlargements count, including those by earlier owners. A designer should calculate the added external roof volume, rather than using the proposed room’s internal floor area as a shortcut.

Roof enlargements cannot exceed the highest part of the existing roof. A dormer or other enlargement extending beyond the plane of an existing roof slope on the principal elevation facing a highway is not permitted under these rights. In practical terms, do not assume a front-facing dormer qualifies. Roof enlargements are also excluded on designated land, including conservation areas and the South Downs National Park.

Similar-looking external materials, side-window privacy conditions and detailed positioning rules also apply. Most dormers must be set back at least 20 centimetres from the original eaves, measured along the roof slope, with exceptions for certain roof forms. Rooflights have separate rules. Check the precise proposal with the Planning Portal and council rather than treating every loft conversion as the same planning operation.

Garden outbuildings and entrance porches

Class E covers buildings and certain other structures within a house’s curtilage for purposes incidental to enjoying the dwellinghouse. A shed, hobby workshop or appropriate garden gym may qualify; a separate dwelling does not. A building’s actual proposed use matters, so do not assume that calling an annexe a summerhouse makes it PD. Seek advice on proposals involving sleeping accommodation or independent living.

Outbuildings must be single storey, with eaves no higher than 2.5 metres. Overall height is limited to 4 metres with a dual-pitched roof or 3 metres with another roof form. If any part is within 2 metres of the curtilage boundary, the whole building must be no higher than 2.5 metres. Buildings forward of the principal elevation are excluded, and the coverage limit must also be satisfied.

Porches have separate rights: the ground-floor area measured externally must not exceed 3 square metres, no part may be higher than 3 metres, and no part may be within 2 metres of a boundary between the dwellinghouse’s curtilage and a highway. A highway can include a footpath, not just the carriageway. These planning limits do not settle whether building regulations approval is needed.

Conservation areas, listed homes and the South Downs

A conservation area does not remove every PD right. Instead, designated-land restrictions rule out certain work, including side extensions, multi-storey extensions and roof enlargements under the usual householder classes. An Article 4 direction may remove further specified rights. Check the actual designation and direction covering your property rather than relying on a neighbour’s recent project.

The South Downs National Park has designated-land restrictions too. Around Findon and other park-edge locations, confirm whether the property lies inside the boundary and which authority handles the proposal. Outbuildings face additional designated-land restrictions; within national parks, buildings more than 20 metres from the house also face a specific combined 10-square-metre area limit. Check the full Class E guidance before siting a garden room.

Listed status brings a separate consent regime. Alterations affecting a listed building’s special interest may need listed building consent even where planning permission is not required. Class E does not grant outbuilding rights within the curtilage of a listed building. Neither a small size nor a position hidden from the road removes these concerns; get advice before committing to a design.

Use a Lawful Development Certificate to document PD

A proposed Lawful Development Certificate, often called an LDC, asks the council to confirm that the described works would be lawful for planning purposes. It is not the same as a planning application judged on design merits. The decision depends on the relevant law, the facts and the evidence supplied, so accurate drawings and a clear record of earlier additions are important.

An LDC is not generally compulsory for PD work, but it can provide useful evidence when selling or remortgaging. Apply before construction where possible, and build to the certified drawings. If the design changes, have those changes checked. A certificate is not a substitute for any required prior approval, building regulations approval, listed building consent or private covenant consent.

When to apply and where to get local advice

If your proposal exceeds a PD limit, a householder planning application may still succeed. Exceeding a limit means you need an assessment, not that the project is automatically unacceptable. The council considers matters such as design, neighbouring amenity and relevant planning policies. The usual decision target is eight weeks from validation, although an agreed extension or unresolved issues can make it longer.

Pre-application advice can help clarify constraints before a full submission. Contact Arun District Council, Chichester District Council, Adur & Worthing Councils or the South Downs National Park Authority, according to the address and relevant planning arrangements. Check each authority’s current service, charges and information requirements. Pre-application comments guide a proposal but are not planning permission or a guarantee of the final decision.

Planning and building regulations are separate checks. Structural safety, fire escape, insulation and drainage can require building control involvement even where planning is covered by PD. Party wall duties, drainage permissions and restrictive covenants may also apply. FirstR8 Builds offers a free, no-obligation initial site consultation and can work from your own plans or with experienced local architects; establish the approval route before agreeing the construction scope.

Frequently asked questions

Does a neighbour’s permission mean I can build under PD?
No. Neighbour agreement does not replace the statutory rules, prior approval or a planning application. It is also separate from any duties under the Party Wall etc. Act 1996.
Can I use the larger rear extension allowance in a conservation area?
No. The larger home extension prior approval route is unavailable on designated land, which includes conservation areas. A smaller proposal may qualify under other rules, or you can seek planning permission.
Does converting an existing garage always need planning permission?
Not always, but check conditions on the original permission, especially requirements to retain parking. External alterations, protected status and any proposal for a separate dwelling can change the position.
Can the council confirm PD through an informal email?
Informal advice can help, but a Lawful Development Certificate provides a formal determination for the proposal described. Ask the council what evidence and drawings it requires.
Where should I check the measurements before applying?
Use the Planning Portal’s project guidance alongside the council’s planning history and constraints information. Have a competent designer check original walls, boundaries, ground levels and cumulative additions against the current rules.